Features |
Open Structure: Ensures high temperature and pressure are contained only within the specimen, enhancing safety and performance.
Safety Protections: Includes liquid level protection, a transparent shield, intelligent water replenishment, and maintenance-free control valves.
Automatic Fault Detection: Identifies faults and provides prompt information for easy troubleshooting.
Quality Construction: Features a 304 SUS cold water tank with chiller and heat exchanger, and a 316 SUS hot water tank with high-quality heating elements.
Optional Functions: Includes options for flow measurement and a pre-tension loading system.
|
Specifications |
Standards: ISO 10508
Pressure Range: 4 to 11 bar
Pressure Control Accuracy: ±0.2 bar
Number of Test Stations: 6
Maximum Pipe Diameter: 2 x 63 mm
Cycle Numbers: 1 to 100,000
Cold Water Tank Temperature: 15℃ to RT (±2℃), 800L
Hot Water Tank Temperature: 60℃ to 95℃ (±1℃), 800L
Display: Touch screen
Control: PLC
|