Superficial Rockwell Hardness Tester

The Superficial Rockwell Hardness Tester includes models PHR-1S, PHR-2S, and PHR-1ST, designed for precision testing of small and thin materials. These testers adhere to the Rockwell hardness testing principles and offer reliable, real results. They are suitable for testing materials such as tinplate, thin steel plates, copper strips, aluminum strips, small stamping parts, and thin carburizing layers.

Non-destructive Testing: The small indentation does not affect the use of most parts, making it effectively non-destructive.

Small and Lightweight: With a minimum weight of 0.7 kg, these testers are versatile for both workshop and field use.

International Standards: Provides accuracy equivalent to desktop models, complying with ISO 6508, ASTM E18, and ASTM E110 standards.

Specifications

Rockwell Initial Test Force: 3 kgf
Rockwell Total Test Force: 15 kgf, 30 kgf, 45 kgf (for PHR-1ST, 15 kgf only)
Rockwell Indenter: 120° Diamond Indenter, 1/16" Carbide Ball Indenter
Accuracy: Complies with ISO 6508, ASTM E18 standards
Test Resolution: Rockwell: 0.5 HR
Test Range: Rockwell: HRN, HRT, HRW, HRX, HRY, etc., 15 scales

Accessories

Standard Assembly

Tester, Bench Stand, 120° Diamond Indenter, 1/16" Carbide Ball Indenter, 3 pcs Rockwell Test Block, 1 pc HR15T Test Block (only for PHR-1ST)

Optional Accessories

1/16", 1/8" Carbide Ball Indenter, 1/4", 1/2" Steel Ball Indenter, Rockwell Hardness Block (HR15T, HR30N, HR30T), Raised Spot Anvil, Slim Raised Spot Anvil (flat top: Φ1.5mm, Φ2.5mm, Φ3.5mm), Diamond Raised Spot Anvil, Ball Testing Anvil, Extension Bar, Spare Magnifier, Flat Adapter (for PHR-1ST), Carrying Case

Model Selection

Model Selection

PHR-1S: Specimen / Opening Size: 25 X 25 mm, Net Weight: Tester: 0.8 kg, Bench Stand: 1.5 kg, Gross Weight: Tester: 3.4 kg, Bench Stand: 1.8 kg, Package Dimensions: Tester: 380 x 360 x 170 mm, Bench Stand: 220 x 150 x 240 mm, The first number in the model specification indicates the largest opening width (inch), and the second number indicates the largest opening depth (inch).

PHR-2S: Specimen / Opening Size: 50 X 50 mm, Net Weight: Tester: 1.1 kg, Bench Stand: 1.5 kg, Gross Weight: Tester: 3.6 kg, Bench Stand: 1.8 kg, Package Dimensions: Tester: 380 x 360 x 170 mm, Bench Stand: 220 x 150 x 240 mm

PHR-1ST: Specimen Diameter > 4.8 mm, Net Weight: Tester: 0.8 kg, Bench Stand: 1.5 kg, Gross Weight: Tester: 3.4 kg, Bench Stand: 1.8 kg, Package Dimensions: Tester: 380 x 360 x 170 mm, Bench Stand: 220 x 150 x 240 mm